Case 177: Difference between revisions

From Echopedia
Jump to navigation Jump to search
No edit summary
m (Replace html5media with gif)
 
Line 4: Line 4:
|Courtesy = [[AMC Echolab, AMC, The Netherlands]]
|Courtesy = [[AMC Echolab, AMC, The Netherlands]]


|filepointer1=<html5media height="350" width="279" autoplay="true" loop="true">File:E00911.mp4</html5media>
|filepointer1=[[File:E00911.gif|350px]]
|file_name1=E00911
|file_name1=E00911
|descriptionfile1=PLAX: subvalvular membrane in left ventricle outflow tract
|descriptionfile1=PLAX: subvalvular membrane in left ventricle outflow tract


|filepointer2=<html5media height="350" width="279" autoplay="true" loop="true">File:E00912.mp4</html5media>
|filepointer2=[[File:E00912.gif|350px]]
|file_name2=E00912
|file_name2=E00912
|descriptionfile2=PLAX with Color Doppler: high velocity flow in left ventricle outflow tract
|descriptionfile2=PLAX with Color Doppler: high velocity flow in left ventricle outflow tract


|filepointer3=<html5media height="350" width="279" autoplay="true" loop="true">File:E00913.mp4</html5media>
|filepointer3=[[File:E00913.gif|350px]]
|file_name3=E00913
|file_name3=E00913
|descriptionfile3=A3CH
|descriptionfile3=A3CH


|filepointer4=<html5media height="350" width="279" autoplay="true" loop="true">File:E00914.mp4</html5media>
|filepointer4=[[File:E00914.gif|350px]]
|file_name4=E00914
|file_name4=E00914
|descriptionfile4=A3CH with Color Doppler
|descriptionfile4=A3CH with Color Doppler


|filepointer5=<html5media height="350" width="279" autoplay="true" loop="true">File:E00915.mp4</html5media>
|filepointer5=[[File:E00915.gif|350px]]
|file_name5=E00915
|file_name5=E00915
|descriptionfile5=Suprasternal view: Collor Doppler, high velocity flow in left ventricle outflow tract
|descriptionfile5=Suprasternal view: Collor Doppler, high velocity flow in left ventricle outflow tract

Latest revision as of 20:13, 1 December 2023

Subvalvular membrane in left ventricle outflow tract
Courtesy of: AMC Echolab, AMC, The Netherlands
E00911.gif E00912.gif
PLAX: subvalvular membrane in left ventricle outflow tract PLAX with Color Doppler: high velocity flow in left ventricle outflow tract
Magnifier.pngenlarge

Ppt logo.pngdownload file to use in your powerpoint presentation

Magnifier.pngenlarge

Ppt logo.pngdownload file to use in your powerpoint presentation

E00913.gif E00914.gif
A3CH A3CH with Color Doppler
Magnifier.pngenlarge

Ppt logo.pngdownload file to use in your powerpoint presentation

Magnifier.pngenlarge

Ppt logo.pngdownload file to use in your powerpoint presentation

E00915.gif
E00917.jpg
Suprasternal view: Collor Doppler, high velocity flow in left ventricle outflow tract Continuous-wave signal of high flow in left ventricle outflow tract
Magnifier.pngenlarge

Ppt logo.pngdownload file to use in your powerpoint presentation