TEE - standard imaging views
Transesophageal Echocardiographic imaging views. Adapted from Shanewise et al. Shanewise
| ME two-chamber | Probe adjustment: neutral | Sector depth: ~14 cm |
|---|---|---|
Primary diagnostic issues
|
Required structures
| |
| ME LAX | Probe adjustment: neutral | Sector depth: ~12 cm |
| image | Primary diagnostic issues
|
Required structures
|
| ME mitral commissural | Probe adjustment: neutral | Sector depth: ~12 cm |
| image | Primary diagnostic issues
|
Required structures
|
| TG mid-SAX | Probe adjustment: neutral | Sector depth: ~12 cm |
| image | Primary diagnostic issues
|
Required structures
|
| TG two-chamber | Probe adjustment: neutral | Sector depth: ~12 cm |
| image | Primary diagnostic issues
|
Required structures
|
| TG RV inflow | Probe adjustment: neutral-rightward | Sector depth: ~12 cm |
| image | Primary diagnostic issues
|
Required structures
|
| TG RV inflow-outflow | Probe adjustment: neutral-rightward | Sector depth: ~14 cm |
| image | Primary diagnostic issues
|
Required structures
|
| TG basal SAX | Probe adjustment: neutral | Sector depth: ~12 cm |
| image | Primary diagnostic issues
|
Required structures
|
| TG LAX | Probe adjustment: neutral-leftward | Sector depth: ~12 cm |
| image | Primary diagnostic issues
|
Required structures
|
| Deep TG LAX | Probe adjustment: neutral | Sector depth: ~16 cm |
| image | Primary diagnostic issues
|
Required structures
|
| ||
References
<biblio>
- Shanewise pmid=10512257
</biblio>