Art Valves: Difference between revisions

2,280 bytes added ,  29 December 2013
no edit summary
No edit summary
No edit summary
Line 14: Line 14:
|}
|}


{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="500px"
{| class="wikitable" cellpadding="0" cellspacing="0" border="0"
|-
|-
!colspan="3"|'''Advantages and disadvantages of mechanical and bioprosthetic'''
!colspan="3"|'''Advantages and disadvantages of mechanical and bioprosthetic'''
Line 23: Line 23:
|-
|-
!valign="top"|Advantages
!valign="top"|Advantages
|valign="top"|Durable
|valign="top"|
*Durable
|
|
*No anticoagulation needed
*No anticoagulation needed
Line 42: Line 43:
*Infection in ring or rim valve (endocarditis).
*Infection in ring or rim valve (endocarditis).
*Pannus (tissue ingrowth)
*Pannus (tissue ingrowth)
|valign="top"|Degeneration is 10-15 years
|valign="top"|
*Degeneration is 10-15 years
|-
|-
|colspan="3"|'''NB: For all valve prostheses is indicated in some cases endocarditis prophylaxis.'''<cite>1</cite>
|colspan="3"|'''NB: For all valve prostheses is indicated in some cases endocarditis prophylaxis.'''<cite>1</cite>
Line 58: Line 60:
==Features of the different prosthetic==
==Features of the different prosthetic==


{| class="wikitable" cellpadding="0" cellspacing="0" border="0"
{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="600px"
|-
|-
!Type of prosthetic valve<cite>1</cite>
!Type of prosthetic valve<cite>1</cite>
Line 68: Line 70:
|
|
*Starr-Edwards
*Starr-Edwards
|many
|Many
|little
|Little
|-
|-
|Tilting disc
|Tilting disc
Line 109: Line 111:


==Postoperative ultrasound==
==Postoperative ultrasound==
After valve replacement have to be at the time that a patient is stable (hemodynamic and metabolism, "no anemia") to be an output echo is made for capturing of valve parameters. Here it is to calculate with use of the art valve diameter, a valve surface is important so that a size is recorded regardless of the cardiac output. (Fever creates a hyperdynamic circulation so the gradients will increase, not the calculated valve area).
After valve replacement have to be at the time that a patient is stable (hemodynamic and metabolism, "no anemia") to be an output echo is made for capturing of valve parameters. Here it is to calculate with use of the art valve diameter, a valve surface is important so that a size is recorded regardless of the cardiac output. (Fever creates a hyperdynamic circulation so the gradients will increase, not the calculated valve area).


Line 115: Line 118:
{| class="wikitable" cellpadding="0" cellspacing="0" border="0"
{| class="wikitable" cellpadding="0" cellspacing="0" border="0"
|-
|-
!Data needed for evaluation of mitraliskunstklep
!Data needed for evaluation of mitral prosthetic valve
!Data needed for evaluation of aortic prosthetic valve
!Data needed for evaluation of aortic prosthetic valve  
|-
|-
|Maximum and mean gradient
|Maximum and mean gradient  
|Maximum and mean gradient
|Maximum and mean gradient  
|-
|-
|MVA calculated with VTI MV, VTI LVOT + LVOT diameter
|MVA calculated with VTI MV, VTI LVOT + LVOT diameter  
|AVA calculated with VTI Ao, LVOT VTI, valve size to use for LVOT diameter
|AVA calculated with VTI Ao, LVOT VTI, valve size to use for LVOT diameter  
|-
|-
|Pressure halftime
|Pressure halftime  
|Paravalvular aoi
|Para valvular aoi  
|-
|-
|Scanning valve ring for paravalvular leakage
|Scanning valve ring para valvular leakage  
|Fistulas, abscesses
|Fistulas, abscesses
|}
|}


{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="600px"
|-
|Video
|Video
|-
!Too much mobility MKV
!Resulting in serious leakage MKV
|}
==Percutaneous Aortic Valve==
Surgical replacement of the aortic valve is an effective treatment modality for patients with degenerative aortic stenosis and calcification. In an aging population, however, there are more and more patients in whom surgery poses a high risk. Due to recent developments, there is a less invasive alternative possible, resulting in a prosthesis (bioprosthesis) of the aorta, through the femoral artery or transapical can be inserted.


{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="600px"
|-
|[[Image:Edw sapien.gif|150px]]
|[[Image:Med corevalve.png|150px]]
|-
!Edwards Sapien<cite>2</cite>
!Medtronic Core Valve<cite>3</cite>
|}
==Echocardiogafie in percutaneous aortic valve==
Preoperative [[Aorta|aortic dimensions]] is all well mapped with an echocardiographic examination, so that the interventional cardiologist knows exactly where the implant is to be placed.<cite>3</cite>
{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="600px"
|-
|[[Image:Med-corevalve2.png|300px]]
|}
Postoperatively is always an echocardiographic examination is necessary to exclude paravalvular leakage. Shortly after placement of a percutaneous valve is almost inevitable that there paravalvular leak is present because the aortic wall where the prosthesis against them is not smooth and round but rough and irregular. A slight paravalvular leakage is still accepted and usually disappears after a few weeks if tissue has grown over the prosthesis. In severe paravalvular leakage is the probability that the prosthesis becomes loose it big so it must be replaced.
{| class="wikitable" cellpadding="0" cellspacing="0" border="0" width="600px"
|-
|Video
|Video
|-
|Paravalvular leakage
|}


==References==
==References==
<biblio>
<biblio>
#1 R.B.A, van den Brink ‘Kunstkleppen' in "Praktische echocardiografie",Hamer, J.P.M, Pieper P.G, et al, 2e druk, 2009, Houten, Bohn Stafleu van Loghum, DOI: 10.1007/978-90-313-7565-3_9, Print ISBN: 978-90-313-6235-6
#1 R.B.A, van den Brink ‘Kunstkleppen' in "Praktische echocardiografie",Hamer, J.P.M, Pieper P.G, et al, 2e druk, 2009, Houten, Bohn Stafleu van Loghum, DOI: 10.1007/978-90-313-7565-3_9, Print ISBN: 978-90-313-6235-6
#2 [http://www.edwards.com/presentationvideos/2007annualreport/prodCarpAscen.html Edwards SAPIEN Transcatheter Heart Valve & Ascendra Delivery System]
#3 [http://www.medtronic.nl/aandoeningen/hartklepaandoening/product-therapie/producten-hartklepvervanging-reparatie/CoreValve-transkatheter-hartklep/index.htm The CoreValve ® transcatheter-heart valve]
</biblio>
</biblio>
0

edits