LV Contrast: Difference between revisions

Jump to navigation Jump to search
no edit summary
(Created page with "left ventricular contrast Contrast echocardiography is used to improve the picture quality and at the same time provides information on myocardial perfusion. Contrast echocar...")
 
No edit summary
Line 1: Line 1:
left ventricular contrast
Contrast echocardiography is used to improve the picture quality and at the same time provide information on myocardial perfusion. Contrast echocardiography can save the patient for further invasive investigations. Because in addition to improving quality contrast, echocardiography provides a secure and comprehensive investigation of cardiac structure, function and coronary flow reserve.


Contrast echocardiography is used to improve the picture quality and at the same time provides information on myocardial perfusion. Contrast echocardiography can save the patient for further invasive investigations . Because in addition to improving quality contrast echocardiography provides a secure and comprehensive investigation of cardiac structure , function and coronary flow reserve .
Contrast echocardiography is used to enhance the echogenicity of blood (better signal/noise ratio) and is used only in patients in whom no contrast has delivered (if there are 2 or more segments of LV myocardium are not to judge) any result. Contrast does the left ventricle white highlight and enhance the outline of the endocardial border, which reduces the accuracy in detection or exclusion of abnormalities increases.


Contrast echocardiography is used to enhance the echogenicity of blood (better signal / noise ratio) and is used only in patients in whom no contrast has delivered ( if there are 2 or more segments of LV myocardium are not to judge ) any result. Contrast does the left ventricle white highlight and enhance the outline of the endocardial border , which reduces the accuracy in detection or exclusion of abnormalities increases .
{| class="wikitable" cellpadding="0" cellspacing="0" border="0"
|+ Indication/contra-indication
|-
!Contra-indications for LV contrast
|-
|
*<7 days after acute coronary syndrome
*Significant shunt (suspected or proven)
*Hyper Sensitive LV contrast
*Intracoronary lesion
 |}


Indication / contraindication
{| class="wikitable" cellpadding="0" cellspacing="0" border="0"
Contraindications for LV contrast
|-
< 7 days after acute coronary syndrome
!Indications for LV contrast
Significant shunt ( suspected or proven )
|-
Hyper Sensitive LV contrast
|
Intracoronary lesion
*Abnormal LV structure and function<nowiki>*</nowiki>
 
*LV volume and ejection fraction<nowiki>*</nowiki>
*Apical hypertrophic CMP
*Non - compaction CMP
*Apical thrombus
*LV pseudoaneurysm
|-
|<nowiki>*</nowiki>At suboptimal 2D images to enhance image quality
|}


Indications for LV contrast
==Mechanical index==
Abnormal LV structure and function *
Transducers generate an acoustic field by a high input (power) of emitted sound waves (vibrations). One measure of this is the mechanical index. High mechanical index destroy the contrast bubbles. Therefore, a reduction in the input of the sound waves transmitted is a necessary.
LV volume and ejection fraction *
Apical hypertrophic CMP
Non - compaction CMP
apical thrombus
LV pseudoaneurysm
* At suboptimal 2D images to enhance image quality
 
mechanical index
Transducers generate an acoustic field by a high input (power ) of emitted sound waves ( vibrations ) . One measure of this is the mechanical index . High mechanical index destroyed the contrast bubbles . Therefore, it is therefore important to reduce . The input of the sound waves transmitted in a necessity


example
==Example==
 
Source: European Journal of Echocardiography (2009 ) 10, 194-212


{| class="wikitable" cellpadding="0" cellspacing="0" border="0"
|-
|Video
|Video
|}


==References==
==References==
<biblio>
<biblio>
#1 pmid=22941889
#1 pmid=19270054
</biblio>
</biblio>
0

edits

Navigation menu